Commit Graph
23 Commits
Author SHA1 Message Date
rattusandGitHub 519c941165 Prs/lora reservations (reduce massive Lora reservations especially on Flux2) (#11069)
* mp: only count the offload cost of math once

This was previously bundling the combined weight storage and computation
cost

* ops: put all post async transfer compute on the main stream

Some models have massive weights that need either complex
dequantization or lora patching. Don't do these patchings on the offload
stream, instead do them on the main stream to syncrhonize the
potentially large vram spikes for these compute processes. This avoids
having to assume a worst case scenario of multiple offload streams
all spiking VRAM is parallel with whatever the main stream is doing.
2025-12-03 02:28:45 -05:00
rattusandGitHub 73f5649196 Implement temporal rolling VAE (Major VRAM reductions in Hunyuan and Kandinsky) (#10995)
* hunyuan upsampler: rework imports

Remove the transitive import of VideoConv3d and Resnet and takes these
from actual implementation source.

* model: remove unused give_pre_end

According to git grep, this is not used now, and was not used in the
initial commit that introduced it (see below).

This semantic is difficult to implement temporal roll VAE for (and would
defeat the purpose). Rather than implement the complex if, just delete
the unused feature.

(venv) rattus@rattus-box2:~/ComfyUI$ git log --oneline
220afe33 (HEAD) Initial commit.
(venv) rattus@rattus-box2:~/ComfyUI$ git grep give_pre
comfy/ldm/modules/diffusionmodules/model.py:                 resolution, z_channels, give_pre_end=False, tanh_out=False, use_linear_attn=False,
comfy/ldm/modules/diffusionmodules/model.py:        self.give_pre_end = give_pre_end
comfy/ldm/modules/diffusionmodules/model.py:        if self.give_pre_end:

(venv) rattus@rattus-box2:~/ComfyUI$ git co origin/master
Previous HEAD position was 220afe33 Initial commit.
HEAD is now at 9d8a8179 Enable async offloading by default on Nvidia. (#10953)
(venv) rattus@rattus-box2:~/ComfyUI$ git grep give_pre
comfy/ldm/modules/diffusionmodules/model.py:                 resolution, z_channels, give_pre_end=False, tanh_out=False, use_linear_attn=False,
comfy/ldm/modules/diffusionmodules/model.py:        self.give_pre_end = give_pre_end
comfy/ldm/modules/diffusionmodules/model.py:        if self.give_pre_end:

* move refiner VAE temporal roller to core

Move the carrying conv op to the common VAE code and give it a better
name. Roll the carry implementation logic for Resnet into the base
class and scrap the Hunyuan specific subclass.

* model: Add temporal roll to main VAE decoder

If there are no attention layers, its a standard resnet and VideoConv3d
is asked for, substitute in the temporal rolloing VAE algorithm. This
reduces VAE usage by the temporal dimension (can be huge VRAM savings).

* model: Add temporal roll to main VAE encoder

If there are no attention layers, its a standard resnet and VideoConv3d
is asked for, substitute in the temporal rolling VAE algorithm. This
reduces VAE usage by the temporal dimension (can be huge VRAM savings).
2025-12-02 22:49:29 -05:00
rattusandGitHub 277237ccc1 attention: use flag based OOM fallback (#11038)
Exception ref all local variables for the lifetime of exception
context. Just set a flag and then if to dump the exception before
falling back.
2025-12-02 17:24:19 -05:00
rattusandGitHub 0ff0457892 mm: wrap the raw stream in context manager (#10958)
The documentation of torch.foo.Stream being usable with with: suggests
it starts at version 2.7. Use the old API for backwards compatibility.
2025-11-28 16:38:12 -05:00
rattusandGitHub 3f382a4f98 quant ops: Dequantize weight in-place (#10935)
In flux2 these weights are huge (200MB). As plain_tensor is a throw-away
deep copy, do this multiplication in-place to save VRAM.
2025-11-27 08:06:30 -08:00
rattusandGitHub f17251bec6 Account for the VRAM cost of weight offloading (#10733)
* mm: default to 0 for NUM_STREAMS

Dont count the compute stream as an offload stream. This makes async
offload accounting easier.

* mm: remove 128MB minimum

This is from a previous offloading system requirement. Remove it to
make behaviour of the loader and partial unloader consistent.

* mp: order the module list by offload expense

Calculate an approximate offloading temporary VRAM cost to offload a
weight and primary order the module load list by that. In the simple
case this is just the same as the module weight, but with Loras, a
weight with a lora consumes considerably more VRAM to do the Lora
application on-the-fly.

This will slightly prioritize lora weights, but is really for
proper VRAM offload accounting.

* mp: Account for the VRAM cost of weight offloading

when checking the VRAM headroom, assume that the weight needs to be
offloaded, and only load if it has space for both the load and offload
 * the number of streams.

As the weights are ordered from largest to smallest by offload cost
this is guaranteed to fit in VRAM (tm), as all weights that follow
will be smaller.

Make the partial unload aware of this system as well by saving the
budget for offload VRAM to the model state and accounting accordingly.
Its possible that partial unload increases the size of the largest
offloaded weights, and thus needs to unload a little bit more than
asked to accomodate the bigger temp buffers.

Honor the existing codes floor on model weight loading of 128MB by
having the patcher honor this separately withough regard to offloading.
Otherwise when MM specifies its 128MB minimum, MP will see the biggest
weights, and budget that 128MB to only offload buffer and load nothing
which isnt the intent of these minimums. The same clamp applies in
case of partial offload of the currently loading model.
2025-11-27 01:03:03 -05:00
rattusandGitHub 94c298f962 flux: reduce VRAM usage (#10737)
Cleanup a bunch of stack tensors on Flux. This take me from B=19 to B=22
for 1600x1600 on RTX5090.
2025-11-13 16:02:03 -08:00
rattusandGitHub 1c7eaeca10 qwen: reduce VRAM usage (#10725)
Clean up a bunch of stacked and no-longer-needed tensors on the QWEN
VRAM peak (currently FFN).

With this I go from OOMing at B=37x1328x1328 to being able to
succesfully run B=47 (RTX5090).
2025-11-12 16:20:53 -05:00
rattusandGitHub 18e7d6dba5 mm/mp: always unload re-used but modified models (#10724)
The partial unloader path in model re-use flow skips straight to the
actual unload without any check of the patching UUID. This means that
if you do an upscale flow with a model patch on an existing model, it
will not apply your patchings.

Fix by delaying the partial_unload until after the uuid checks. This
is done by making partial_unload a model of partial_load where extra_mem
is -ve.
2025-11-12 16:19:53 -05:00
rattusandGitHub c350009236 ops: Put weight cast on the offload stream (#10697)
This needs to be on the offload stream. This reproduced a black screen
with low resolution images on a slow bus when using FP8.
2025-11-09 22:52:11 -05:00
rattusandGitHub cf97b033ee mm: guard against double pin and unpin explicitly (#10672)
As commented, if you let cuda be the one to detect double pin/unpinning
it actually creates an asyc GPU error.
2025-11-06 21:20:48 -05:00
rattusandGitHub a389ee01bb caching: Handle None outputs tuple case (#10637) 2025-11-04 14:14:10 -08:00
rattusandGitHub 135fa49ec2 Small speed improvements to --async-offload (#10593)
* ops: dont take an offload stream if you dont need one

* ops: prioritize mem transfer

The async offload streams reason for existence is to transfer from
RAM to GPU. The post processing compute steps are a bonus on the side
stream, but if the compute stream is running a long kernel, it can
stall the side stream, as it wait to type-cast the bias before
transferring the weight. So do a pure xfer of the weight straight up,
then do everything bias, then go back to fix the weight type and do
weight patches.
2025-11-01 18:48:53 -04:00
rattusandGitHub 513b0c46fb Add RAM Pressure cache mode (#10454)
* execution: Roll the UI cache into the outputs

Currently the UI cache is parallel to the output cache with
expectations of being a content superset of the output cache.
At the same time the UI and output cache are maintained completely
seperately, making it awkward to free the output cache content without
changing the behaviour of the UI cache.

There are two actual users (getters) of the UI cache. The first is
the case of a direct content hit on the output cache when executing a
node. This case is very naturally handled by merging the UI and outputs
cache.

The second case is the history JSON generation at the end of the prompt.
This currently works by asking the cache for all_node_ids and then
pulling the cache contents for those nodes. all_node_ids is the nodes
of the dynamic prompt.

So fold the UI cache into the output cache. The current UI cache setter
now writes to a prompt-scope dict. When the output cache is set, just
get this value from the dict and tuple up with the outputs.

When generating the history, simply iterate prompt-scope dict.

This prepares support for more complex caching strategies (like RAM
pressure caching) where less than 1 workflow will be cached and it
will be desirable to keep the UI cache and output cache in sync.

* sd: Implement RAM getter for VAE

* model_patcher: Implement RAM getter for ModelPatcher

* sd: Implement RAM getter for CLIP

* Implement RAM Pressure cache

Implement a cache sensitive to RAM pressure. When RAM headroom drops
down below a certain threshold, evict RAM-expensive nodes from the
cache.

Models and tensors are measured directly for RAM usage. An OOM score
is then computed based on the RAM usage of the node.

Note the due to indirection through shared objects (like a model
patcher), multiple nodes can account the same RAM as their individual
usage. The intent is this will free chains of nodes particularly
model loaders and associate loras as they all score similar and are
sorted in close to each other.

Has a bias towards unloading model nodes mid flow while being able
to keep results like text encodings and VAE.

* execution: Convert the cache entry to NamedTuple

As commented in review.

Convert this to a named tuple and abstract away the tuple type
completely from graph.py.
2025-10-30 17:39:02 -04:00
rattusandGitHub ab7ab5be23 Fix Race condition in --async-offload that can cause corruption (#10501)
* mm: factor out the current stream getter

Make this a reusable function.

* ops: sync the offload stream with the consumption of w&b

This sync is nessacary as pytorch will queue cuda async frees on the
same stream as created to tensor. In the case of async offload, this
will be on the offload stream.

Weights and biases can go out of scope in python which then
triggers the pytorch garbage collector to queue the free operation on
the offload stream possible before the compute stream has used the
weight. This causes a use after free on weight data leading to total
corruption of some workflows.

So sync the offload stream with the compute stream after the weight
has been used so the free has to wait for the weight to be used.

The cast_bias_weight is extended in a backwards compatible way with
the new behaviour opt-in on a defaulted parameter. This handles
custom node packs calling cast_bias_weight and defeatures
async-offload for them (as they do not handle the race).

The pattern is now:

cast_bias_weight(... , offloadable=True) #This might be offloaded
thing(weight, bias, ...)
uncast_bias_weight(...)

* controlnet: adopt new cast_bias_weight synchronization scheme

This is nessacary for safe async weight offloading.

* mm: sync the last stream in the queue, not the next

Currently this peeks ahead to sync the next stream in the queue of
streams with the compute stream. This doesnt allow a lot of
parallelization, as then end result is you can only get one weight load
ahead regardless of how many streams you have.

Rotate the loop logic here to synchronize the end of the queue before
returning the next stream. This allows weights to be loaded ahead of the
compute streams position.
2025-10-29 17:17:46 -04:00
rattusandGitHub d202c2ba74 execution: Allow a subgraph nodes to execute multiple times (#10499)
In the case of --cache-none lazy and subgraph execution can cause
anything to be run multiple times per workflow. If that rerun nodes is
in itself a subgraph generator, this will crash for two reasons.

pending_subgraph_results[] does not cleanup entries after their use.
So when a pending_subgraph_result is consumed, remove it from the list
so that if the corresponding node is fully re-executed this misses
lookup and it fall through to execute the node as it should.

Secondly, theres is an explicit enforcement against dups in the
addition of subgraphs nodes as ephemerals to the dymprompt. Remove this
enforcement as the use case is now valid.
2025-10-28 16:22:08 -04:00
rattusandGitHub 4739d7717f execution: fold in dependency aware caching / Fix --cache-none with loops/lazy etc (Resubmit) (#10440)
* execution: fold in dependency aware caching

This makes --cache-none compatiable with lazy and expanded
subgraphs.

Currently the --cache-none option is powered by the
DependencyAwareCache. The cache attempts to maintain a parallel
copy of the execution list data structure, however it is only
setup once at the start of execution and does not get meaninigful
updates to the execution list.

This causes multiple problems when --cache-none is used with lazy
and expanded subgraphs as the DAC does not accurately update its
copy of the execution data structure.

DAC has an attempt to handle subgraphs ensure_subcache however
this does not accurately connect to nodes outside the subgraph.
The current semantics of DAC are to free a node ASAP after the
dependent nodes are executed.

This means that if a subgraph refs such a node it will be requed
and re-executed by the execution_list but DAC wont see it in
its to-free lists anymore and leak memory.

Rather than try and cover all the cases where the execution list
changes from inside the cache, move the while problem to the
executor which maintains an always up-to-date copy of the wanted
data-structure.

The executor now has a fast-moving run-local cache of its own.
Each _to node has its own mini cache, and the cache is unconditionally
primed at the time of add_strong_link.

add_strong_link is called for all of static workflows, lazy links
and expanded subgraphs so its the singular source of truth for
output dependendencies.

In the case of a cache-hit, the executor cache will hold the non-none
value (it will respect updates if they happen somehow as well).

In the case of a cache-miss, the executor caches a None and will
wait for a notification to update the value when the node completes.

When a node completes execution, it simply releases its mini-cache
and in turn its strong refs on its direct anscestor outputs, allowing
for ASAP freeing (same as the DependencyAwareCache but a little more
automatic).

This now allows for re-implementation of --cache-none with no cache
at all. The dependency aware cache was also observing the dependency
sematics for the objects and UI cache which is not accurate (this
entire logic was always outputs specific).

This also prepares for more complex caching strategies (such as RAM
pressure based caching), where a cache can implement any freeing
strategy completely independently of the DepedancyAwareness
requirement.

* main: re-implement --cache-none as no cache at all

The execution list now tracks the dependency aware caching more
correctly that the DependancyAwareCache.

Change it to a cache that does nothing.

* test_execution: add --cache-none to the test suite

--cache-none is now expected to work universally. Run it through the
full unit test suite. Propagate the server parameterization for whether
or not the server is capabale of caching, so that the minority of tests
that specifically check for cache hits can if else. Hard assert NOT
caching in the else to give some coverage of --cache-none expected
behaviour to not acutally cache.
2025-10-22 15:49:05 -04:00
rattus128andGitHub b1467da480 execution: fold in dependency aware caching / Fix --cache-none with loops/lazy etc (#10368)
* execution: fold in dependency aware caching

This makes --cache-none compatiable with lazy and expanded
subgraphs.

Currently the --cache-none option is powered by the
DependencyAwareCache. The cache attempts to maintain a parallel
copy of the execution list data structure, however it is only
setup once at the start of execution and does not get meaninigful
updates to the execution list.

This causes multiple problems when --cache-none is used with lazy
and expanded subgraphs as the DAC does not accurately update its
copy of the execution data structure.

DAC has an attempt to handle subgraphs ensure_subcache however
this does not accurately connect to nodes outside the subgraph.
The current semantics of DAC are to free a node ASAP after the
dependent nodes are executed.

This means that if a subgraph refs such a node it will be requed
and re-executed by the execution_list but DAC wont see it in
its to-free lists anymore and leak memory.

Rather than try and cover all the cases where the execution list
changes from inside the cache, move the while problem to the
executor which maintains an always up-to-date copy of the wanted
data-structure.

The executor now has a fast-moving run-local cache of its own.
Each _to node has its own mini cache, and the cache is unconditionally
primed at the time of add_strong_link.

add_strong_link is called for all of static workflows, lazy links
and expanded subgraphs so its the singular source of truth for
output dependendencies.

In the case of a cache-hit, the executor cache will hold the non-none
value (it will respect updates if they happen somehow as well).

In the case of a cache-miss, the executor caches a None and will
wait for a notification to update the value when the node completes.

When a node completes execution, it simply releases its mini-cache
and in turn its strong refs on its direct anscestor outputs, allowing
for ASAP freeing (same as the DependencyAwareCache but a little more
automatic).

This now allows for re-implementation of --cache-none with no cache
at all. The dependency aware cache was also observing the dependency
sematics for the objects and UI cache which is not accurate (this
entire logic was always outputs specific).

This also prepares for more complex caching strategies (such as RAM
pressure based caching), where a cache can implement any freeing
strategy completely independently of the DepedancyAwareness
requirement.

* main: re-implement --cache-none as no cache at all

The execution list now tracks the dependency aware caching more
correctly that the DependancyAwareCache.

Change it to a cache that does nothing.

* test_execution: add --cache-none to the test suite

--cache-none is now expected to work universally. Run it through the
full unit test suite. Propagate the server parameterization for whether
or not the server is capabale of caching, so that the minority of tests
that specifically check for cache hits can if else. Hard assert NOT
caching in the else to give some coverage of --cache-none expected
behaviour to not acutally cache.
2025-10-17 13:55:15 -07:00
rattus128andGitHub 95ca2e56c8 WAN2.2: Fix cache VRAM leak on error (#10308)
Same change pattern as 7e8dd275c243ad460ed5015d2e13611d81d2a569
applied to WAN2.2

If this suffers an exception (such as a VRAM oom) it will leave the
encode() and decode() methods which skips the cleanup of the WAN
feature cache. The comfy node cache then ultimately keeps a reference
this object which is in turn reffing large tensors from the failed
execution.

The feature cache is currently setup at a class variable on the
encoder/decoder however, the encode and decode functions always clear
it on both entry and exit of normal execution.

Its likely the design intent is this is usable as a streaming encoder
where the input comes in batches, however the functions as they are
today don't support that.

So simplify by bringing the cache back to local variable, so that if
it does VRAM OOM the cache itself is properly garbage when the
encode()/decode() functions dissappear from the stack.
2025-10-13 15:23:11 -04:00
rattus128andGitHub 4965c0e2ac WAN: Fix cache VRAM leak on error (#10141)
If this suffers an exception (such as a VRAM oom) it will leave the
encode() and decode() methods which skips the cleanup of the WAN
feature cache. The comfy node cache then ultimately keeps a reference
this object which is in turn reffing large tensors from the failed
execution.

The feature cache is currently setup at a class variable on the
encoder/decoder however, the encode and decode functions always clear
it on both entry and exit of normal execution.

Its likely the design intent is this is usable as a streaming encoder
where the input comes in batches, however the functions as they are
today don't support that.

So simplify by bringing the cache back to local variable, so that if
it does VRAM OOM the cache itself is properly garbage when the
encode()/decode() functions dissappear from the stack.
2025-10-01 18:42:16 -04:00
rattus128andGitHub 911331c06c sd: fix VAE tiled fallback VRAM leak (#10139)
When the VAE catches this VRAM OOM, it launches the fallback logic
straight from the exception context.

Python however refs the entire call stack that caused the exception
including any local variables for the sake of exception report and
debugging. In the case of tensors, this can hold on the references
to GBs of VRAM and inhibit the VRAM allocated from freeing them.

So dump the except context completely before going back to the VAE
via the tiler by getting out of the except block with nothing but
a flag.

The greately increases the reliability of the tiler fallback,
especially on low VRAM cards, as with the bug, if the leak randomly
leaked more than the headroom needed for a single tile, the tiler
would fallback would OOM and fail the flow.
2025-10-01 18:40:28 -04:00
rattus128andGitHub 653ceab414 Reduce Peak WAN inference VRAM usage - part II (#10062)
* flux: math: Use _addcmul to avoid expensive VRAM intermediate

The rope process can be the VRAM peak and this intermediate
for the addition result before releasing the original can OOM.
addcmul_ it.

* wan: Delete the self attention before cross attention

This saves VRAM when the cross attention and FFN are in play as the
VRAM peak.
2025-09-27 18:14:16 -04:00
rattus128andGitHub e42682b24e Reduce Peak WAN inference VRAM usage (#9898)
* flux: Do the xq and xk ropes one at a time

This was doing independendent interleaved tensor math on the q and k
tensors, leading to the holding of more than the minimum intermediates
in VRAM. On a bad day, it would VRAM OOM on xk intermediates.

Do everything q and then everything k, so torch can garbage collect
all of qs intermediates before k allocates its intermediates.

This reduces peak VRAM usage for some WAN2.2 inferences (at least).

* wan: Optimize qkv intermediates on attention

As commented. The former logic computed independent pieces of QKV in
parallel which help more inference intermediates in VRAM spiking
VRAM usage. Fully roping Q and garbage collecting the intermediates
before touching K reduces the peak inference VRAM usage.
2025-09-16 19:21:14 -04:00